Siemens Emotion 16 CT-Scanner

Siemens Emotion 16 CT-Scanner

The Siemens Emotion 16 CT-Scanner offers an affordable solution for high resolution images, a long life cycle, fast patient throughout, and much more.

Product Description

The Siemens Emotion 16 CT-Scanner offers an affordable CT solution for high resolution images, a long life cycle, fast patient throughput, and a wide range of clinical imaging applications. A refurbished used Siemens Emotion 16 CT will provide your imaging department with a powerful, cost-effective, multi-slice CT scanner with a comprehensive range of applications. The Siemens Emotion 16 features a 70cm aperture, 50cm scan field, and a patient table with a weight capacity of up 440 lbs (200 kg).

Features

  • SafeCT Low-dose Solution
  • 16-slice acquisition
  • Wide range of clinical applications
  • Fast and efficient with 0.6 second rotation time
  • Multislice UFC detector
  • 0.75 or 1.5mm slices per rotation in less than 20 seconds
  • Small diagnostic detail for acquisition
  • 105 millisecond temporal resolution for clear depiction of blood vessels
  • Scan any anatomy with a single breathhold
  • Pathology seen from any perspective
  • Low patient dose

Clinical Applications

  • Abdominal, Adult Cardiac, Functional Imaging, Pediatrics, Pelvis, Spinal, Thoracic

Technology

  • syngo LungCARE CT with NEX (Nodule Enhanced Viewing)
  • syngo Colonography with PEV (Polyp Enhanced Viewing)

Specifications

Gantry

  • Gantry Generation: 3rd
  • Slipring: Low voltage
  • Aperture: 70 cm
  • FOV: 50 cm (standard), 70 cm (optional)
  • Tilt range: ±30 degrees
  • Type of positioning lights: Laser
  • Accuracy of positioning lights: ±1 mm
  • Focus-detector distance: 940 mm

X-Ray Tube

  • Type/Make: Siemens Dura 422MV Siemens Straton
  • Focal spot size(s) quoted to (X-RAY TUBE): 0.5 mm x 0.8 mm
  • IEC 336/93 standard (X-RAY TUBE) 0.7 x 0.8
  • Settings at which focal spot change automatically; small changes
  • kW = kV x mA / 1000: up to 28 kW ; large up to 45 kW
  • Total filtration (inherent + beam shaping filter) at central axis (mm Al equivalent) (X-RAY TUBE) 6.3 (140kV)
  • Anode heat capacity (MHU): 5
  • Maximum anode cooling rate (kHU/min): 810
  • Method of cooling (X-RAY TUBE) Oil to air
  • Guaranteed tube life: 200,000 scan seconds
  • Detector type: Solid state (Ultra Fast Ceramic)
  • Maximum number of simultaneously acquired data sets (no. of slices): 16
  • Number of detectors per row (Maximum anode cooling rate): 736 (1472 channels)
  • Number of elements along z-axis (Maximum anode cooling rate): 24
  • Effective length of each element at isocentre: 16 x 0.6 mm, 8 x 1.2 mm
  • Total effective length of detector array at isocentre: 19.2 mm
  • Option for more slices / rotation (Maximum anode cooling rate): Yes

Generator/ Power

  • X-ray generator: VAC Power Needed
  • Type: High frequency
  • Location: Rotation assembly (Composition)
  • Power rating – kV settings available (Maximum weight allowed on couch): 50, 80, 110, 130 kW
  • mA range and step size (Weight bearing properties) 20-345(1mA steps)
  • Maximum mA allowed for each kV (Weight bearing properties) 80 kV: 345 mA

Main Console

  • Monitor/ Screen Size: 19 inches
  • Number of monitors at console (functions of each if > 1) (Image monitor) Up to 6 (shared database)
  • Image area matrix dimensions: 1024 x 1024
  • Usual range of CT number displayed (HU) (Image monitor) (-10,240 to 30,710 if metal implants)
  • Accuracy of distance measurements in x-y plane: depends on pixel size (mm)
  • Weighted CTDI (CTDIw or CTDIvol) displayed on console: Yes
  • Dose Length Product (DLP) displayed on console (Dose information): Yes
  • Geometric Efficiency displayed on console when <70% (Dose information) >70% for all collimations
  • Control methods: Mouse, keyboard